HVAC sizing add-on

HVAC load calculation software for insulation contractors.

A foam-sealed house needs less tonnage. NvelopIQ's HVAC load calculation software sizes the equipment for the envelope you are actually installing, based on ACCA Manual J/S/D/T methods, and it reuses your foam takeoff so the house is never measured twice.

Add-on price: from $200 per run

Why it matters to you

Oversized HVAC makes a good foam job look bad.

Seal the attic, stop the air leaks, and the load drops. If the HVAC is still sized by a rule of thumb, the equipment is too big for the house. It short-cycles, never runs long enough to pull humidity out, and the homeowner calls about clammy rooms and uneven temperatures. Guess who gets blamed.

Right-sizing the system to the new envelope prevents that. The house ends up efficient and comfortable, and you become the builder's whole-house performance partner instead of just the foam sub.

  • No short-cycling

    Equipment that fits the load runs full cycles.

  • Humidity under control

    Longer run times pull moisture out of the air.

  • A selling point to builders

    Envelope plus right-sized HVAC is a house that performs. You can show it on paper.

Try it

Same house. Watch the tonnage step down.

An illustrative example, not a load calculation. Pick a sizing method and see where the load comes from.

Same 2,400 sf house, three ways to size it

Illustrative, not a load calc

3.5 ton

Leaky envelope and ducts in a hot attic drive the load.

Cooling load by source, Btu/h

  • Windows 9,800
  • Air leakage 9,400
  • Ducts 8,200
  • Roof / ceiling 6,400
  • Walls 4,100
  • People + appliances 3,900

Total 41,800

What's included

Load calc, equipment, ducts and registers.

Based on ACCA Manual J, S, D and T methods, built from the foam takeoff you already ran.

  • Manual J

    Load calculation

    Room-by-room heating and cooling loads for the house as you are insulating it, not as it would be with batts.

  • Manual S

    Equipment selection

    Equipment matched to those loads, so the system runs long enough to dehumidify instead of short-cycling.

  • Manual D

    Duct design

    Trunks and runs sized for the airflow each room needs, drawn on M-1/M-2 layout sheets.

  • Manual T

    Registers

    Supply and return registers picked for each room.

What you get

A report the builder and the HVAC sub can use.

  • Permit-style report: loads, equipment, ducts, registers
  • Duct layout drawings on M-1/M-2 sheets
  • 3D duct model
  • Reuses the foam takeoff: no second measurement

Why do foam houses need less?

Read Why foam houses need smaller HVAC: Manual J after air sealing for the load-by-load breakdown. Pair it with a REScheck on the same upload, and bid the whole envelope.

Manual J, Manual S, Manual D and Manual T are standards published by ACCA. NvelopIQ's HVAC sizing is based on ACCA methods; it is not affiliated with, endorsed by or certified by ACCA. Your jurisdiction decides what it accepts for a permit, and a licensed HVAC professional should review the design before install.

Foam the house. Size it right.

The private beta is open to spray foam and insulation contractors. Bring a real plan set and see what comes back.

Join the beta Sample